CDWLN - 9967, VANADIUM REFERENCE STANDARD SOLUTION(SUPDAT)
- MSDS: CDWLN
- Manufacturer: FISHER SCIENTIFIC CO
- Product Name: 9967, VANADIUM REFERENCE STANDARD SOLUTION(SUPDAT)
- National Stock Number: 6810-00N056722
Product Identification
Product ID:9967, VANADIUM REFERENCE STANDARD SOLUTION(SUPDAT)
MSDS Date:04/12/1991
FSC:6810
NIIN:00N056722
MSDS Number: CDWLN
Responsible Party
FAIR LAWN, NJ 07410-2802
US
Emergency Phone: 201-796-7100;800-424-9300(CHEMTREC)
Info Phone: 201-796-7100
Cage: 1B464
Contractor
Telephone: 201-796-7100
Cage: 1B464
Ingredients
HYDROGEN CHLORIDE (HYDROCHLORIC ACID) (SARA 302/313)
CAS: 7647-01-0
RTECS: MW4025000
Fraction By Weight: 6.1%
OSHA PEL C 5 PPM
ACGIH TLV: C 5 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
VANADIUM PENTOXIDE (SARA 302) (CERCLA)
CAS: 1314-62-1
RTECS: YW2450000
Fraction By Weight: 0.16%
OSHA PEL C,0.5 MG/M3
ACGIH TLV: 0.05 MG/M3 RDUST
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 93.7%
OSHA PEL N/K
ACGIH TLV: N/K
DO NOT USE WATER
RTECS: 9999999ZZ
USE WATER SPRAY/FOG IN FLOODING AMTS. USE WATER SPRAY
RTECS: 9999999ZZ
WATER FROM AS FAR A DIST AS POSS. AVOID BREATHING
RTECS: 9999999ZZ
SPECIFIC INFORMATION CONTACT NEHC .
RTECS: 9999999ZZ
INFLAMM, ULCERATION, NECROSIS & CHEM BURNS.
RTECS: 9999999ZZ
COLLAPSE. PHOTOSENSIT RXNS MAY OCCUR IN PERSONS
RTECS: 9999999ZZ
CONT MAY CAUSE SEV IRRIT, CONJ,
RTECS: 9999999ZZ
DROP OF HYDROCHLORIC ACID SPLASHED IN EYE & IMMED
RTECS: 9999999ZZ
CONJ EPITHELIUM. ANIMALS EXPOS TO VAP CONCS OF 1350
RTECS: 9999999ZZ
FOR 6 HRS SHOWED SLIGHT EROSION OF CORNEAL
RTECS: 9999999ZZ
ACID MAY CAUSE BURNS OF MOUTH, THROAT, ESOPHAGUS &
RTECS: 9999999ZZ
VOMIT, DIARR, CHILLS, SHOCK & INTENSE THRIST,
RTECS: 9999999ZZ
CIRCULATORY COLLAPSE MAY OCCUR. DEATH MAY BE DUE TO
RTECS: 9999999ZZ
PRLNGD EXPOS MAY CAUSE EROSION & DISCOLORATION OF
RTECS: 9999999ZZ
PRLNGD CONT W/VAPS/DILUTE SOLNS MAY CAUSE DERM.
RTECS: 9999999ZZ
FOR 6 HRS DAILY FOR 50 DAYS SHOWED ONLY SLIGHT
RTECS: 9999999ZZ
DEPENDENT UPON CONC & DURATION OF EXPOS. CONJ/EFTS
RTECS: 9999999ZZ
SKIN CONTACT WITH THIS SUBSTANCE.
RTECS: 9999999ZZ
100 FOLD TO RENDER IT HARMLESS TO TISSUES.
RTECS: 9999999ZZ
POISONING, 12TH ED.). GET MED ATTN IMMED. IF VOMIT
RTECS: 9999999ZZ
NO SPECIFIC ANTIDOTE. TREAT SYMPTOMATICALLY
RTECS: 9999999ZZ
& FULL LENGTH FACESHIELD .
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:GAS/FUMES @ LEVELS OF 5-35
PPM MAY CAUSE IRRIT & BURNING OF THROAT, COUGH & CHOKING; 50-100
PPM MAY BE BARELY TOLERABLE FOR 1 HR. HIGH LEVELS MAY CAUSE INFLAMM
& OCCASNLY ULCERATION OF NOS E, THROAT/LARYNX, BRONCH, PNEUM,
PALPITATIONS & HDCH. HIGHER CONCS MAY CAUSE NECROSIS OF TRACHEA, &
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:BRONCH EPITHELIUM, NASOSEPTAL
PERFORATION, ATELECTASIS, EMPHYSEMA, DMG TO PULM BLOOD VESS &
LESIONS OF LIVER & OTHER ORGANS. DEATH MAY BE DUE TO LARYNGEAL
SPASM, BRONCHOPNEUM/PULM EDEMA. 1300 -2000 PPM MAY BE DANGEROUS
EVEN ON BRIEF EXPOS. REPROD EFTS RPTD IN ANIMALS. SKIN:MAY CAUSE
SEV IRRITATION,(ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE OXYG/ARTF
RESP) . EYES:IMMED FLUSH W/POTABLE WATER FOR @ LST 15 MIN, SEEK
ASSISTANCE FROM MD . SKIN:FLUSH W/COPIOUS AMTS OF WATER. CALL MD (F
P N). INGEST:DO NOT USE GASTRIC LAVAGE/EMESIS. DILUTE ACID IMMED BY
DRINKING LG QTYS OF WATER/MILK. IF VOMIT PERSISTS, ADMIN FLUIDS
REPEATEDLY. INGESTED ACID MUST BE DILUTED APPROXIMATELY (ING 22)
Fire Fighting
Extinguishing Media:DRY CHEM, CO*2, WATER SPRAY/REGULAR FOAM. LGR
FIRES, USE WATER SPRAY, FOG/REGULAR FOAM (1990 EMER RESPONSE
(SUPDAT)
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NEGLIGIBLE FIRE HAZARD WHEN EXPOSED TO
HEAT OR FLAME.
Accidental Release
Spill Release Procedures:OCCUPATIONAL SPILL:COVER WITH SODA ASH. SCOOP
UP AND PLACE IN A SUITABLE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:PROVIDE LOCAL EXHAUST/PROCESS ENCLOSURE VENT TO MEET
PUBLISHED EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 25)
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . WEAR
APPROP PROT (IMPERVIOUS) CLTHG & EQUIP TO PVNT POSSIBILITY OF (ING
21)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE NAME/PART NO:1000 PPM. EXTING MEDIA:GUIDEBOOK, DOT P 5800.5).
MOVE CNTNR FROM FIRE AREA IF CAN BE DONE W/OUT RISK. APPLY COOLING
WATER TO SIDES OF CNTNRS THAT ARE EXPOS TO FLAMES UNTIL WELL AFTER
FIRE IS OUT. STAY AWAY FROM ENDS OF TANKS (1990 EMER RESPONSE
GUIDEBOOK, DOT P 5800.5, GUIDE PAGE 601. (ING 4)
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Vapor Pres:14 @ 20C
Vapor Density:0.7 (H*2O)
Spec Gravity:1.0
Evaporation Rate & Reference:>1 (ETHER =1)
Solubility in Water:COMPLETELY
Appearance and Odor:GREEN-YELLOW LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
ACETIC ANHYDROIDE, ALCOHOLIC HYDROGEN CYANIDE, ALUMINUM,
ALUMINIUM-TITANIUM ALLOYS, 2-AMINOETHANOL. FOR MORE (ING 7)
Stability Condition to Avoid:STABLE UNDER NORMAL TEMPERATURES AND
PRESSURES.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY RELEASE
CORROSIVE HYDROGEN CHLORIDE.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.